In a vacuum boiling evaporator, the fresh water generated is pumped out by ().
A、a brine pump
B、an air ejector
C、a feed water pump
D、a condensate pump
A、a brine pump
B、an air ejector
C、a feed water pump
D、a condensate pump
A、Sea water is heated to boiling temperature under a vacuum B、Sea water is passed over heated plates in a thin film C、Heated sea water is injected into a vacuum chamber D、Sea water is forced through a heated eductor
A、Sea water is heated to boiling temperature while under a vacuum B、Sea water is passed over heated plates in a thin film C、Heated sea water is injected into a vacuum chamber D、Sea water is forced through a heated eductor
A、A.boiling and cavitations; low temperature B、B.boiling and cavitations; pressurized C、C.leaking and boiling; low temperature D、D.leaking and boiling; pressurized
A、higher boiling temperature for a given pressure than does a pure refrigerant B、lower boiling temperature for a given pressure than does a pure refrigerant C、boiling pressure equal to that of a pure refrigerant at a given pressure D、boiling point will not be affected by entrained oil
A、vacuum drag from the auxiliary condensate system B、individual vacuum pumps C、a single non-condensing air ejector D、a two stage air ejector