【单选题】

Ignition failure in an automatically controlled auxiliary boiler could be caused by()

A、carbon deposits on the flame scanner

B、high fuel oil temperature

C、low fuel oil viscosity

D、high steam pressure

更多“Ignition failure in an automatically controlled auxiliary boiler could be caused by()”相关的问题
第1题

A、A.smoky exhaust  B、B.starting failure  C、C.ignition relay  D、D.over speed  

点击查看答案
第2题

A、An increase in compression ratio will increase the ignition lag  B、An increase in compression ratio will decrease the ignition lag  C、A decrease in compression ratio will decrease the ignition lag  D、A decrease in ignition lag will increase the compression ratio  

点击查看答案
第3题

A、It produces a warning for new failures before advising for CRITICAL and HIGH failures.  B、It ignores new failures and considers the failures listed in the last LIST FAILURE command only.  C、It produces an error with recommendation to run the LIST FAILURE command before the ADVISE FAILURE command.  D、It produces advice only for new failures and the failures listed in the last LIST FAILURE command are ignored.  

点击查看答案
第4题

A、A.ignition failure  B、B.oxygen corrosion of the fuel lines  C、C.the pistons to seize  D、D.blue smoke  

点击查看答案
第5题

A、A.a burned out solenoid in the oil supply valve  B、B.high temperature excess air  C、C.incorrectly setting the hot-well dump valve  D、D.an incorrectly positioned burner snubber realy  

点击查看答案
第6题

A、The CHANGE FAILURE command has detected new failures recorded in the Automatic Diagnostic Repository(ADR)  B、The VALIDATE DATABASE command has detected new failures recorded in the Automatic Diagnostic Repository (ADR)  C、The ADVISE FAILURE command has detected new failures recorded in the Automatic Diagnostic Repository (ADR) since the last LIST FAILURE  D、The RECOVER command has detected new failures recorded in the Automatic Diagnostic Repository (ADR) since the last LIST FAILURE command was executed  

点击查看答案
第7题

A、Another repair session is running concurrently.  B、The failure ID has not been mentioned in the command for data file 5.  C、There are new failures recorded in the Automatic Diagnostic Repository (ADR).  D、The ADVISE FAILURE command has not been issued before the REPAIR FAILURE command.  

点击查看答案
第8题

A、Transactions and queries accessing database objects contained in any tablespace stored in DGROUP1 will fall.  B、Mirroring of allocation units will be done to ASM disks in the CONTROLLER2 failure group until the CONTROLLER1 for failure group is brought back online.  C、The data in the CONTROLLER1 failure group is copied to the controller2 failure group and rebalancing is initiated.  D、ASM does not mirror any data until the controller failure group is brought back online, and newly allocated primary allocation units (AU) are stored in the controller2 failure group, without mirroring.  E、Transactions accessing database objects contained in any tablespace stored in DGROUP1 will fail but queries will succeed.  

点击查看答案
第9题

A、excessive purging before lighting off  B、insufficient trail for ignition period  C、a faulty transformer in the ignition circuit  D、insufficient purging before lighting off  

点击查看答案
客服
TOP

请使用微信扫码支付

订单号:
遇到问题请联系在线客服