The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().

A、system is low on refrigerant

B、high pressure cutout switch is improperly adjusted

C、discharge valves are leaking slightly

D、discharge valves are leaking excessively

更多“The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().”相关的问题
第1题

A、A.increasing refrigerant pressure in the coil  B、B.increasing chilled water flow through the cooler  C、C.sub-cooling the refrigerant in the condenser  D、D.superheating the refrigerant in the compressor  

点击查看答案
第2题

A、stop the refrigerant from flowing  B、force the refrigerant to flow  C、cause the refrigerant pressure to rise  D、cause the refrigerant pressure to fall  

点击查看答案
第3题

A、A.too much refrigerant in the system  B、B.oil entrained in the refrigerant  C、C.less than a full charge of refrigerant in the system  D、D.ice crystals forming in the refrigerant  

点击查看答案
第4题

A、passing it through the expansion valve  B、condensing refrigerant in the system condenser  C、passing the gaseous refrigerant through the heat interchanger on the suction side of the compressor  D、maintaining a high pressure on the systems receiver  

点击查看答案
第5题

A、sudden evaporation of wax crystals in the lubricant  B、sudden evaporation of entrapped air in the lubricant  C、release of refrigerant from the oil/refrigerant mixture  D、release of dissolved lubricant from the refrigerant  

点击查看答案
第6题

A、a shortage of compressor oil  B、warm food in the refrigerator  C、excessive condenser cooling water  D、a shortage of refrigerant  

点击查看答案
第7题

A、remove any air that may accumulate in the system  B、take out unpleasant fumes from the refrigerant  C、vent off excess refrigerant in an emergency  D、permit opening the refrigerating system for cleaning and inspecting  

点击查看答案
第8题

A、refrigerant pressure in the evaporator  B、cooling water temperature to the condenser  C、heat load in the refrigerator compartment  D、solenoid valve in the liquid line  

点击查看答案
第9题

A、A.increase the amount of cooling water to the condenser  B、B.decrease the amount of cooling water to the condenser  C、C.add more refrigerant to the system  D、D.remove some refrigerant from the system  

点击查看答案
第10题

A、a shortage of refrigerant  B、the compressor running continuously  C、liquid refrigerant returning to the compressor  D、the compressor short cycling on the high pressure cutout  

点击查看答案
客服
TOP

请使用微信扫码支付

订单号:
遇到问题请联系在线客服